AD-AC Series: Single Pole — Surge Protection Device

DynaShield® AD-AC Series: Single Pole Surge Suppression

ALLTEC’s AD-AC series surge protection devices are particularly effective in high lightning environments where critical equipment is exposed to large surges or transients.

These heavy-duty suppression circuits are UL recognized Type 1ca (UL 1449th edition) and offer a convenient DIN rail mounted base with replaceable suppression protection modules.

For maximum safety, it relies on fast-acting, high-energy dissipating thermally protected metal oxide varistors and employ arc quenching technology for maximum safety. A visual status window is included to monitor the AD-AC ‘s operation.

Shop Now
Versatile application enhances electrical/ electronic equipment load reliability by:
  • Lowering equipment maintenance costs
  • Reducing operational downtime
  • Preventing lightning induced hardware failures
Increases return on investment (ROI) by:
  • Extending equipment life expectancy
  • Lowering the number of insurance claims
  • Extending Equipment Mean Time Between Failure (MTBF)
  • Eliminating costs associated with service calls

DynaShield Applications

ALLTEC’s Protection Pyramid depends on DynaShield® products to support its comprehensive facility framework. The second tier of protection diminishes the significance of random high-energy, short-duration electrical power transients through properly installed surge protective devices. These occurrences are typically caused by atmospheric phenomena (such as lightning strikes), utility switching, inductive loads, and internally generated overvoltages. You can view typical installation locations in the application maps to the right by locating the numbers 5 and 6.

Model AD150-
AC (-S)
AD180-
AC (-S)
AD-275A-
AC (-S)
AD320-
AC (-S)
AD385-
AC (-S)
AD420-
AC (-S)
AD550-
AC (-S)
AD690-
AC (-S)
Tested to IEC 61643-11:2012; ANSI/UL 1449 4th Edition
Category UL Type 1ca
Number of Ports Single Port Device
Technology Thermally Protected MOV
Maximum Continuous Operating Voltage Uc (AC/DC) 150 V 180 V 275 V 320 V 385 V 420 V 550 V 690 V
Nominal Discharge Current In (8 x 20 μs) 20 kA
Maximum Discharge Current Imax (8 x 20 μs) Type 2 50 kA 40 kA
Voltage Protection Level @ 3 kA (8 x 20 μs) < 0.7 kV < 1.0 kV < 1.0 kV < 1.2 kV < 1.5 kV < 1.5 kV < 1.8 kV < 2.5 kV
UL Short Circuit Current Rating (SCCR) 200 kA
Response Time < 25 ns
Recommended Over-Current Protection Device 125A gL/gG Fuse
Visual Status Indication Windows: Green = Normal, Red = Replace
Contact switch for remote annunciation Change over contact
Contact switch capacity

AC: 250V/0.5 A
DC: 250V/0.1A; 125V/0.2 A; 75V/0.5A

Location Category Indoor Only
Method of Mounting Fixed 35 mm DIN rail, Reference EN 50022/DIN 46277-3
Dimension (H x W x D) 90 mm x 18 mm x 64.3 mm
3.5”x 0.7”x 2.5”
1 module, DIN 43880
Weight (Max) 0.33 kg
0.74 lb
Maximum Wire Size Single strand 35 mm2 (#2 AWG)
Multi strand 25 mm2 (#4 AWG)
Striping Length Terminals 10 mm (0.375”)
Torque Terminals 0.8 Nm (0.6 ft-lb)
Maximum Wire Size Contacts 1.5 mm2 (#16 AWG)
Stripping Length Contacts 7 mm (0.25”)
Torque Contacts 0.2 Nm (0.5 ft-lb)
Operating Temperature -40°C to +85°C
Relative Humidity ≤ 95% non-condensing
Altitude ≤ 2000 m (6562 ft)
Enclosure Protection Rating IP 20
Housing Flammability Rating Thermoplastic; flammability rating: UL 94 V-0
Certifications RoHS Compliant

* -S for remote annunciation dry contacts

Contact us to find out what risk mitigation products & services work best for your industry.